opnsense-src/sys/dev/usb/quirk
Steffen Dirkwinkel 8580e334b0
umodem: ignore CDC_CM descriptor for baltech smartcard reader
The CDC_CM descriptor points to the wrong interface for serial port use.
Ignore it to use the CDC_UNION descriptor.

usbconfig dump (spec at: https://usb.org/sites/default/files/CDC1.2_WMC1.1_012011.zip):
ugen0.2: <Baltech AG Smartcard Reader> at usbus0, cfg=0 md=HOST spd=FULL (12Mbps) pwr=ON (300mA)

  bLength = 0x0012
  bDescriptorType = 0x0001
  bcdUSB = 0x0200
  bDeviceClass = 0x0000  <Probed by interface class>
  bDeviceSubClass = 0x0000
  bDeviceProtocol = 0x0000
  bMaxPacketSize0 = 0x0040
  idVendor = 0x13ad
  idProduct = 0xf019
  bcdDevice = 0x0100
  iManufacturer = 0x0001  <Baltech AG>
  iProduct = 0x0002  <Smartcard Reader>
  iSerialNumber = 0x0003  <45031910>
  bNumConfigurations = 0x0001

 Configuration index 0

    bLength = 0x0009
    bDescriptorType = 0x0002
    wTotalLength = 0x0064
    bNumInterfaces = 0x0003
    bConfigurationValue = 0x0001
    iConfiguration = 0x0000  <no string>
    bmAttributes = 0x0080
    bMaxPower = 0x0096

    Interface 0
      bLength = 0x0009
      bDescriptorType = 0x0004
      bInterfaceNumber = 0x0000
      bAlternateSetting = 0x0000
      bNumEndpoints = 0x0001
      bInterfaceClass = 0x0003  <HID device>
      bInterfaceSubClass = 0x0000
      bInterfaceProtocol = 0x0000
      iInterface = 0x0000  <no string>

      Additional Descriptor

      bLength = 0x09
      bDescriptorType = 0x21
      bDescriptorSubType = 0x11
       RAW dump:
       0x00 | 0x09, 0x21, 0x11, 0x01, 0x00, 0x01, 0x22, 0xd0,
       0x08 | 0x00

     Endpoint 0
        bLength = 0x0007
        bDescriptorType = 0x0005
        bEndpointAddress = 0x0081  <IN>
        bmAttributes = 0x0003  <INTERRUPT>
        wMaxPacketSize = 0x0040
        bInterval = 0x0001
        bRefresh = 0x0000
        bSynchAddress = 0x0000

      Additional Descriptor

      bLength = 0x08
      bDescriptorType = 0x0b
      bDescriptorSubType = 0x01
       RAW dump:
       0x00 | 0x08, 0x0b, 0x01, 0x02, 0x02, 0x02, 0x00, 0x00

    Interface 1
      bLength = 0x0009
      bDescriptorType = 0x0004
      bInterfaceNumber = 0x0001
      bAlternateSetting = 0x0000
      bNumEndpoints = 0x0001
      bInterfaceClass = 0x0002  <Communication device>
      bInterfaceSubClass = 0x0002
      bInterfaceProtocol = 0x0000
      iInterface = 0x0000  <no string>

      Additional Descriptor

      bLength = 0x05
      bDescriptorType = 0x24
      bDescriptorSubType = 0x00
       RAW dump:
       0x00 | 0x05, 0x24, 0x00, 0x10, 0x01

      Additional Descriptor

      bLength = 0x04
      bDescriptorType = 0x24
      bDescriptorSubType = 0x02
       RAW dump:
       0x00 | 0x04, 0x24, 0x02, 0x00

      Additional Descriptor

      bLength = 0x05
      bDescriptorType = 0x24
      bDescriptorSubType = 0x06
       RAW dump:
       0x00 | 0x05, 0x24, 0x06, 0x01, 0x02

      Additional Descriptor

      bLength = 0x05
      bDescriptorType = 0x24
      bDescriptorSubType = 0x01
       RAW dump:
       0x00 | 0x05, 0x24, 0x01, 0x00, 0x01

     Endpoint 0
        bLength = 0x0007
        bDescriptorType = 0x0005
        bEndpointAddress = 0x0085  <IN>
        bmAttributes = 0x0003  <INTERRUPT>
        wMaxPacketSize = 0x0008
        bInterval = 0x0010
        bRefresh = 0x0000
        bSynchAddress = 0x0000

    Interface 2
      bLength = 0x0009
      bDescriptorType = 0x0004
      bInterfaceNumber = 0x0002
      bAlternateSetting = 0x0000
      bNumEndpoints = 0x0002
      bInterfaceClass = 0x000a  <CDC-data>
      bInterfaceSubClass = 0x0000
      bInterfaceProtocol = 0x0000
      iInterface = 0x0000  <no string>

     Endpoint 0
        bLength = 0x0007
        bDescriptorType = 0x0005
        bEndpointAddress = 0x0086  <IN>
        bmAttributes = 0x0002  <BULK>
        wMaxPacketSize = 0x0040
        bInterval = 0x0000
        bRefresh = 0x0000
        bSynchAddress = 0x0000

     Endpoint 1
        bLength = 0x0007
        bDescriptorType = 0x0005
        bEndpointAddress = 0x0006  <OUT>
        bmAttributes = 0x0002  <BULK>
        wMaxPacketSize = 0x0040
        bInterval = 0x0000
        bRefresh = 0x0000
        bSynchAddress = 0x0000

Reviewed by:		manu
MFC after:		1 week
Sponsored by:		Beckhoff Automation GmbH & Co. KG
Differential Revision:	https://reviews.freebsd.org/D37942
2023-01-18 12:17:17 +01:00
..
usb_quirk.c umodem: ignore CDC_CM descriptor for baltech smartcard reader 2023-01-18 12:17:17 +01:00