Inspired by r338025, just remove the element size parameter to the
MODULE_PNP_INFO macro entirely. The 'table' parameter is now required to
have correct pointer (or array) type. Since all invocations of the macro
already had this property and the emitted PNP data continues to include the
element size, there is no functional change.
Mostly done with the coccinelle 'spatch' tool:
$ cat modpnpsize0.cocci
@normaltables@
identifier b,c;
expression a,d,e;
declarer MODULE_PNP_INFO;
@@
MODULE_PNP_INFO(a,b,c,d,
-sizeof(d[0]),
e);
@singletons@
identifier b,c,d;
expression a;
declarer MODULE_PNP_INFO;
@@
MODULE_PNP_INFO(a,b,c,&d,
-sizeof(d),
1);
$ rg -l MODULE_PNP_INFO -- sys | \
xargs spatch --in-place --sp-file modpnpsize0.cocci
(Note that coccinelle invokes diff(1) via a PATH search and expects diff to
tolerate the -B flag, which BSD diff does not. So I had to link gdiff into
PATH as diff to use spatch.)
Tinderbox'd (-DMAKE_JUST_KERNELS).
The timespecadd(3) family of macros were imported from NetBSD back in
r35029. However, they were initially guarded by #ifdef _KERNEL. In the
meantime, we have grown at least 28 syscalls that use timespecs in some
way, leading many programs both inside and outside of the base system to
redefine those macros. It's better just to make the definitions public.
Our kernel currently defines two-argument versions of timespecadd and
timespecsub. NetBSD, OpenBSD, and FreeDesktop.org's libbsd, however, define
three-argument versions. Solaris also defines a three-argument version, but
only in its kernel. This revision changes our definition to match the
common three-argument version.
Bump _FreeBSD_version due to the breaking KPI change.
Discussed with: cem, jilles, ian, bde
Differential Revision: https://reviews.freebsd.org/D14725
Base gcc fails to compile sys/dev/drm2/i915/intel_display.c for i386,
with the following -Werror warnings:
cc1: warnings being treated as errors
/usr/src/sys/dev/drm2/i915/intel_display.c:8884: warning:
initialization from incompatible pointer type
This is due to https://gcc.gnu.org/bugzilla/show_bug.cgi?id=36432, which
incorrectly interprets the [] as a flexible array member.
Because base gcc does not have a -W flag to suppress this particular
warning, it requires a rather ugly cast. To not influence any other
compiler, put it in a #if/#endif block.
Reviewed by: kib
MFC after: 3 days
Differential Revision: https://reviews.freebsd.org/D15744
opt_compat.h is mentioned in nearly 180 files. In-progress network
driver compabibility improvements may add over 100 more so this is
closer to "just about everywhere" than "only some files" per the
guidance in sys/conf/options.
Keep COMPAT_LINUX32 in opt_compat.h as it is confined to a subset of
sys/compat/linux/*.c. A fake _COMPAT_LINUX option ensure opt_compat.h
is created on all architectures.
Move COMPAT_LINUXKPI to opt_dontuse.h as it is only used to control the
set of compiled files.
Reviewed by: kib, cem, jhb, jtl
Sponsored by: DARPA, AFRL
Differential Revision: https://reviews.freebsd.org/D14941
Make vm_wait() take the vm_object argument which specifies the domain
set to wait for the min condition pass. If there is no object
associated with the wait, use curthread' policy domainset. The
mechanics of the wait in vm_wait() and vm_wait_domain() is supplied by
the new helper vm_wait_doms(), which directly takes the bitmask of the
domains to wait for passing min condition.
Eliminate pagedaemon_wait(). vm_domain_clear() handles the same
operations.
Eliminate VM_WAIT and VM_WAITPFAULT macros, the direct functions calls
are enough.
Eliminate several control state variables from vm_domain, unneeded
after the vm_wait() conversion.
Scetched and reviewed by: jeff
Tested by: pho
Sponsored by: The FreeBSD Foundation, Mellanox Technologies
Differential revision: https://reviews.freebsd.org/D14384
These functions deal the same type of overflows we do with mallocarray(9).
Using our mallocarray will panic, which different from the previous
behavior (returning NULL), but neither behavior is more correct.
As a sidenote, drm_calloc_large() is not currently used at all.
Reviewed by: dumbbell
Differential Revision: https://reviews.freebsd.org/D13835
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
GPUs: radeonkms, i915kms
NICs: if_em, if_igb, if_bnxt
This metadata isn't used yet, but it will be handy to have later to
implement automatic module loading.
Reviewed by: imp, mmacy
Sponsored by: Dell EMC Isilon
Differential Revision: https://reviews.freebsd.org/D12488
accepts PQ_NONE as the specified queue and returns a Boolean indicating
whether the page's wire count transitioned to zero. Use these features
in dev/drm2.
Reviewed by: kib, markj
MFC after: 1 week
kern_yield(0) effectively causes the calling thread to be rescheduled
immediately since it resets the thread's priority to the highest possible
value. This can cause livelocks when the pattern
"while (!trylock()) kern_yield(0);" is used since the thread holding the
lock may linger on the runqueue for the CPU on which the looping thread is
running.
MFC after: 1 week
The intended use is to annotate frequently used globals which either rarely
change (and thus can be grouped in the same cacheline) or are an atomic counter
(which means it may benefit from being the only variable in the cacheline).
Linker script support is provided only for amd64. Architectures without it risk
having other variables put in, i.e. as if they were not annotated. This is
harmless from correctness point of view.
Reviewed by: bde (previous version)
MFC after: 1 month
If system starts without attached monitor, DRM create framebuffer
for VT console. Later, when monitor is attached, the hotplug event must
issue full modeset procedure to setup CRTC.
In original code, this was done in drm_fb_helper_set_par(), but we don't
have this function implemented yet. Use unrolled version of
drm_fb_helper_set_par() to ensure same functionality.
MFC after: 1 month
In particular, the fault access type is accounted for when the
aperture page is moved to GTT domain. On the other hand, the current
pager structure is left intact, most important, only one page is
instantiated per populate call.
Reviewed by: alc
Sponsored by: The FreeBSD Foundation
MFC after: 3 weeks
Suppose that we have an exclusively busy page, and a thread which can
accept shared-busy page. In this case, typical code waiting for the
page xbusy state to pass is
again:
VM_OBJECT_WLOCK(object);
...
if (vm_page_xbusied(m)) {
vm_page_lock(m);
VM_OBJECT_WUNLOCK(object); <---1
vm_page_busy_sleep(p, "vmopax");
goto again;
}
Suppose that the xbusy state owner locked the object, unbusied the
page and unlocked the object after we are at the line [1], but before we
executed the load of the busy_lock word in vm_page_busy_sleep(). If it
happens that there is still no waiters recorded for the busy state,
the xbusy owner did not acquired the page lock, so it proceeded.
More, suppose that some other thread happen to share-busy the page
after xbusy state was relinquished but before the m->busy_lock is read
in vm_page_busy_sleep(). Again, that thread only needs vm_object lock
to proceed. Then, vm_page_busy_sleep() reads busy_lock value equal to
the VPB_SHARERS_WORD(1).
In this case, all tests in vm_page_busy_sleep(9) pass and we are going
to sleep, despite the page being share-busied.
Update check for m->busy_lock == VPB_UNBUSIED in vm_page_busy_sleep(9)
to also accept shared-busy state if we only wait for the xbusy state to
pass.
Merge sequential if()s with the same 'then' clause in
vm_page_busy_sleep().
Note that the current code does not share-busy pages from parallel
threads, the only way to have more that one sbusy owner is right now
is to recurse.
Reported and tested by: pho (previous version)
Reviewed by: alc, markj
Sponsored by: The FreeBSD Foundation
MFC after: 1 week
Differential revision: https://reviews.freebsd.org/D8196
just with INVARIANTS
rwatson's point was valid in the sense that if the data passed at runtime is
invalid, it should always trip the invariant, not just in the debug case.
This is a deterrent against malicious input, or input caused by hardware
errors.
MFC after: 4 days
X-MFC with: r302577
Requested by: rwatson
Sponsored by: EMC / Isilon Storage Division
By definition (enum __drm_capabilities), cases other than CAP_SYS_ADMIN
aren't possible. Add in a KASSERT safety belt and return false in
!INVARIANTS case if an invalid value is passed in, as it would be a
programmer error.
This fixes a -Wreturn-type error with gcc 5.3.0.
Differential Revision: https://reviews.freebsd.org/D7188
MFC after: 1 week
Reported by: devel/amd64-gcc (5.3.0)
Reviewed by: dumbbell
Sponsored by: EMC / Isilon Storage Division
That check wasn't enough to handle appending a two byte character
following it.
This prevented my T400 (Intel Core 2 Duo P8400) from attaching;
it would panic from a stack overflow detection.
MacBookPro and i915kms_load="YES" in /boot/loader.conf.
A lowlevel timeout in one of the display ports caused an infinite wait
because a ticks/jiffies comparison was constant. The clock subsystem
which makes ticks/jiffies increment is started after the initial
driver probing is done. Refer to sys/kernel.h and SI_SUB_DRIVERS vs
SI_SUB_CLOCKS .
Discussed with: kmacy @
bus_get_cpus() returns a specified set of CPUs for a device. It accepts
an enum for the second parameter that indicates the type of cpuset to
request. Currently two valus are supported:
- LOCAL_CPUS (on x86 this returns all the CPUs in the package closest to
the device when DEVICE_NUMA is enabled)
- INTR_CPUS (like LOCAL_CPUS but only returns 1 SMT thread for each core)
For systems that do not support NUMA (or if it is not enabled in the kernel
config), LOCAL_CPUS fails with EINVAL. INTR_CPUS is mapped to 'all_cpus'
by default. The idea is that INTR_CPUS should always return a valid set.
Device drivers which want to use per-CPU interrupts should start using
INTR_CPUS instead of simply assigning interrupts to all available CPUs.
In the future we may wish to add tunables to control the policy of
INTR_CPUS (e.g. should it be local-only or global, should it ignore
SMT threads or not).
The x86 nexus driver exposes the internal set of interrupt CPUs from the
the x86 interrupt code via INTR_CPUS.
The ACPI bus driver and PCI bridge drivers use _PXM to return a suitable
LOCAL_CPUS set when _PXM exists and DEVICE_NUMA is enabled. They also and
the global INTR_CPUS set from the nexus driver with the per-domain set from
_PXM to generate a local INTR_CPUS set for child devices.
Reviewed by: wblock (manpage)
Differential Revision: https://reviews.freebsd.org/D5519
The local of the same name would alias the global, but we didn't even include
the header that defines tsc_freq. Include it and rename the local.
Reported by: Coverity
CID: 1331559
Sponsored by: EMC / Isilon Storage Division
pagers fault routines always return with a result page, be it the
proper and valid result page, or initially passed freshly allocated
placeholder. Do not free the passed in page until we are able to
provide the replacement, and do not assign NULL to *mres.
Reported and tested by: dumbbell
Reviewed by: royger (who also verified that Xen code is safe)
Sponsored by: The FreeBSD Foundation
This write came from Linux commit b4ae3f22d238 which has been implicated
in Sandy Bridge power consumption issues (albeit under different
conditions on Linux). Disabling it restores normal power consumption on
my Sandy Bridge laptop (Thinkpad X220).
PR: 207889
Reviewed by: cem, dumbbell
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D5665
This makes sure the default context of each ring is cleaned up with the
ring itself and fixes a memory leak.
Author: Mika Kuoppala <mika.kuoppala@linux.intel.com>
Date: Fri May 3 16:29:08 2013 +0300
drm/i915: unreference default context on module unload
Before module unload is called, gpu_idle() will switch
to default context. This will increment ref count of base
object as the default context is 'running' on module unload
time. Unreference the drm object so that when context
is freed, base object is freed as well.
v2: added comment to explain the refcounts (Ben Widawsky)
Signed-off-by: Mika Kuoppala <mika.kuoppala@intel.com>
Reviewed-by: Ben Widawsky <ben@bwidawsk.net>
Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Obtained from: Linux
This fixes several memory leaks. Apparently, this problem exists in
Linux 3.8 but the code changed in Linux 3.9 so it may be fixed upstream
already. Still, this is something we need to pay attention to.
... when __wait_seqno() is interrupted by a signal. In this case,
__wait_seqno() returns -ERESTARTSYS. Like we already do in drm_ioctl(),
we need to convert this error to a common code such as -EINTR, so the
page fault handler is restarted.
Reported by: Frederic Chardon <chardon.frederic@gmail.com>
Tested by: Frederic Chardon <chardon.frederic@gmail.com>
This fixes the following error:
kernel: error: [drm:pid1167:drm_release] *ERROR* Device busy: 2
Because of that, drm_lastclose() was not called, leading to a few memory
leaks once the driver was unloaded.
MFC after: 1 week
This update brings initial support for Haswell GPUs.
Tested by: Many users of FreeBSD, PC-BSD and HardenedBSD
Relnotes: yes
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D5554
taskqueue_enqueue() was changed to support both fast and non-fast
taskqueues 10 years ago in r154167. It has been a compat shim ever
since. It's time for the compat shim to go.
Submitted by: Howard Su <howard0su@gmail.com>
Reviewed by: sephe
Differential Revision: https://reviews.freebsd.org/D5131
address and use this mechanism when:
1. kmem_alloc_{attr,contig}() can't find suitable free pages in the physical
memory allocator's free page lists. This replaces the long-standing
approach of scanning the inactive and inactive queues, converting clean
pages into PG_CACHED pages and laundering dirty pages. In contrast, the
new mechanism does not use PG_CACHED pages nor does it trigger a large
number of I/O operations.
2. on 32-bit MIPS processors, uma_small_alloc() and the pmap can't find
free pages in the physical memory allocator's free page lists that are
covered by the direct map. Tested by: adrian
3. ttm_bo_global_init() and ttm_vm_page_alloc_dma32() can't find suitable
free pages in the physical memory allocator's free page lists.
In the coming months, I expect that this new mechanism will be applied in
other places. For example, balloon drivers should use relocation to
minimize fragmentation of the guest physical address space.
Make vm_phys_alloc_contig() a little smarter (and more efficient in some
cases). Specifically, use vm_phys_segs[] earlier to avoid scanning free
page lists that can't possibly contain suitable pages.
Reviewed by: kib, markj
Glanced at: jhb
Discussed with: jeff
Sponsored by: EMC / Isilon Storage Division
Differential Revision: https://reviews.freebsd.org/D4444
instead of GMBUS access for I2C transfers. The GMBUS driver falls back
to this mode when a transfer times out. However, the first transfer to
timeout was sending the request back to itself resulting in an panic due
to recursing on a lock. Fix it to forward the request on to the proper
device. This appears to have been accidentally changed in r277487.
Reported by: Joe Maloney <jmaloney@pcbsd.org>
Reviewed by: adrian, dumbbell, imp
MFC after: 1 week
Differential Revision: https://reviews.freebsd.org/D4599
o With new KPI consumers can request contiguous ranges of pages, and
unlike before, all pages will be kept busied on return, like it was
done before with the 'reqpage' only. Now the reqpage goes away. With
new interface it is easier to implement code protected from race
conditions.
Such arrayed requests for now should be preceeded by a call to
vm_pager_haspage() to make sure that request is possible. This
could be improved later, making vm_pager_haspage() obsolete.
Strenghtening the promises on the business of the array of pages
allows us to remove such hacks as swp_pager_free_nrpage() and
vm_pager_free_nonreq().
o New KPI accepts two integer pointers that may optionally point at
values for read ahead and read behind, that a pager may do, if it
can. These pages are completely owned by pager, and not controlled
by the caller.
This shifts the UFS-specific readahead logic from vm_fault.c, which
should be file system agnostic, into vnode_pager.c. It also removes
one VOP_BMAP() request per hard fault.
Discussed with: kib, alc, jeff, scottl
Sponsored by: Nginx, Inc.
Sponsored by: Netflix
various reasons while executing user commands. After these commands are
completed, the pages backing the relocation regions are unheld.
Since relocation regions do not have to be page aligned, the code in
validate_exec_list() allocates 2 extra page pointers in the array of
held pages populated by vm_fault_quick_hold_pages(). However, the cleanup
code that unheld the pages always assumed that only the buffer size /
PAGE_SIZE pages were used. This meant that non-page aligned buffers would
not unheld the last 1 or 2 pages in the list. Fix this by saving the
number of held pages returned by vm_fault_quick_hold_pages() for each
relocation region and using this count during cleanup.
Reviewed by: dumbbell, kib
MFC after: 1 week
Differential Revision: https://reviews.freebsd.org/D3965
* Remove obsolete drm_agp_*_memory() prototypes.
* Fix comment in drm_fops.c (outisde -> outside).
* Fix some formatting issues in drm_stub.c (spaces -> tabs).
* Add missing case statement (gen == 3) in intel_gpu_reset().
* Restore pci_enable_busmaster() call in the init path (fixes gpu hang on i945GM).
* Replace M_WAITOK with M_NOWAIT when the return value of malloc is checked (may be incorrect).
Submitted by: <s3erios@gmail.com>
Reviewed by: dumbbell
Approved by: dumbbell
Differential Revision: https://reviews.freebsd.org/D3413
release resources (such as unholding pages) when errors occur. Some
recently added error checks return immediately instead of jumping to a
label resulting in leaks. Fix these to jump to a label to do cleanup
instead.
Reviewed by: kib
MFC after: 1 week
Differential Revision: https://reviews.freebsd.org/D3745
The pci bus driver handles the power state, it also manages
configuration state saving and restoring for its child devices. Thus a
PCI device driver does not have to worry about those things. In fact, I
observe a hard system hang when trying to suspend a system with active
radeonkms driver where both the bus driver and radeonkms driver try to
do the same thing. I suspect that it could be because of an access to a
PCI configuration register after the device is placed into D3 state.
Reviewed by: dumbbell, jhb
MFC after: 13 days
Differential Revision: https://reviews.freebsd.org/D3561
While here update the list of devices id to match the one in linux 3.8.13
Reviewed by: dumbbell
Differential Revision: https://reviews.freebsd.org/D3489
Keep a couple of old macros that will be removed lated when the rest of the code
will be updated to 3.8.13 equivalent.
Chase the renamed macros
Reviewed by: dumbbell
Differential Revision: https://reviews.freebsd.org/D3487
define GID_VIDEO in sys/conf.h, and use it together with UID_ROOT
to define DRM_DEV_UID and DRM_DEV_GID in the drmP.h files.
So there is one place where the UID's and GID's are defined.
Submitted by: ed@
Reviewed by: ed@, dumbbell@
Differential Revision: https://reviews.freebsd.org/D3360
devices in /dev/dri/ with this new group.
This will allow ports and users to more easily access to these devices
for OpenGL and OpenCL support.
Reviewed by: dumbbell@
Approved by: dumbbell@
Differential Revision: https://reviews.freebsd.org/D1260