mirror of
https://github.com/opnsense/src.git
synced 2026-05-28 04:12:45 -04:00
Just print a message in acpi_tz_monitor() only when new active state
is different from the previous active state. This reduce tons of 'acpi_tz0: _AC0: temperature 64.0 >= setpoint 64.0' messages. Reviewed by: msmith
This commit is contained in:
parent
75ce322136
commit
dbad09ef38
1 changed files with 5 additions and 2 deletions
|
|
@ -357,9 +357,12 @@ acpi_tz_monitor(struct acpi_tz_softc *sc)
|
|||
newactive = TZ_ACTIVE_NONE;
|
||||
for (i = TZ_NUMLEVELS - 1; i >= 0; i--) {
|
||||
if ((sc->tz_zone.ac[i] != -1) && (temp >= sc->tz_zone.ac[i])) {
|
||||
device_printf(sc->tz_dev, "_AC%d: temperature %d > setpoint %d\n",
|
||||
i, temp, sc->tz_zone.ac[i]);
|
||||
newactive = i;
|
||||
if (sc->tz_active != newactive) {
|
||||
device_printf(sc->tz_dev,
|
||||
"_AC%d: temperature %d.%d >= setpoint %d.%d\n", i,
|
||||
TZ_KELVTOC(temp), TZ_KELVTOC(sc->tz_zone.ac[i]));
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
|
|
|||
Loading…