Document processor errata that affect performance measurement.
This commit is contained in:
parent
269d02f171
commit
3c83ff13e9
1 changed files with 52 additions and 0 deletions
|
|
@ -730,6 +730,58 @@ and the underlying hardware events used.
|
|||
.It Li interrupts Ta Li HW_Int_Rx
|
||||
.It Li unhalted-cycles Ta (unsupported)
|
||||
.El
|
||||
.Sh PROCESSOR ERRATA
|
||||
The following errata affect performance measurement on these
|
||||
processors.
|
||||
These errata are documented in
|
||||
.Rs
|
||||
.%T "Intel® CoreTM Duo Processor and Intel® CoreTM Solo Processor on 65 nm Process"
|
||||
.%B "Specification Update"
|
||||
.%N "Order Number 309222-017"
|
||||
.%D July 2008
|
||||
.%Q "Intel Corporation"
|
||||
.Re
|
||||
.Bl -tag -width indent -compact
|
||||
.It AE19
|
||||
Data prefetch performance monitoring events can only be enabled
|
||||
on a single core.
|
||||
.It AE25
|
||||
Performance monitoring counters that count external bus events
|
||||
may report incorrect values after processor power state transitions.
|
||||
.It AE28
|
||||
Performance monitoring events for retired floating point operations
|
||||
(C1H) may not be accurate.
|
||||
.It AE29
|
||||
DR3 address match on MOVD/MOVQ/MOVNTQ memory store
|
||||
instruction may incorrectly increment performance monitoring count
|
||||
for saturating simd instructions retired (Event CFH).
|
||||
.It AE33
|
||||
Hardware prefetch performance monitoring events may be counted
|
||||
inaccurately.
|
||||
.It AE36
|
||||
The
|
||||
.Li CPU_CLK_UNHALTED
|
||||
performance monitoring event (Event 3CH) counts
|
||||
clocks when the processor is in the C1/C2 processor power states.
|
||||
.It AE39
|
||||
Certain performance monitoring counters related to bus, L2 cache
|
||||
and power management are inaccurate.
|
||||
.It AE51
|
||||
Performance monitoring events for retired instructions (Event C0H) may
|
||||
not be accurate.
|
||||
.It AE67
|
||||
Performance monitoring event
|
||||
.Li FP_ASSIST
|
||||
may not be accurate.
|
||||
.It AE78
|
||||
Performance monitoring event for hardware prefetch requests (Event
|
||||
4EH) and hardware prefetch request cache misses (Event 4FH) may not be
|
||||
accurate.
|
||||
.It AE82
|
||||
Performance monitoring event
|
||||
.Li FP_MMX_TRANS_TO_MMX
|
||||
may not count some transitions.
|
||||
.El
|
||||