add replace battery condition, replace unchecked strcat calls with asprintf (I do not think buffer overflow was possible here, but lets be consistent)
git-svn-id: https://nagiosplug.svn.sourceforge.net/svnroot/nagiosplug/nagiosplug/trunk@225 f882894a-f735-0410-b71e-b25c423dba1c
This commit is contained in:
parent
2898a0ebb6
commit
63ac65ccb8
1 changed files with 50 additions and 52 deletions
|
|
@ -31,7 +31,7 @@
|
|||
* This plugin requires that the UPSD daemon distributed with Russel
|
||||
* Kroll's "Smart UPS Tools" be installed on the remote host. If you
|
||||
* don't have the package installed on your system, you can download
|
||||
* it from http://www.exploits.org/~rkroll/smartupstools
|
||||
* it from http://www.exploits.org/nut
|
||||
*
|
||||
* License Information:
|
||||
*
|
||||
|
|
@ -66,20 +66,21 @@
|
|||
|
||||
#define PORT 3305
|
||||
|
||||
#define UPS_NONE 0 /* no supported options */
|
||||
#define UPS_UTILITY 1 /* supports utility line voltage */
|
||||
#define UPS_BATTPCT 2 /* supports percent battery remaining */
|
||||
#define UPS_STATUS 4 /* supports UPS status */
|
||||
#define UPS_TEMP 8 /* supports UPS temperature */
|
||||
#define UPS_LOADPCT 16 /* supports load percent */
|
||||
#define UPS_NONE 0 /* no supported options */
|
||||
#define UPS_UTILITY 1 /* supports utility line voltage */
|
||||
#define UPS_BATTPCT 2 /* supports percent battery remaining */
|
||||
#define UPS_STATUS 4 /* supports UPS status */
|
||||
#define UPS_TEMP 8 /* supports UPS temperature */
|
||||
#define UPS_LOADPCT 16 /* supports load percent */
|
||||
|
||||
#define UPSSTATUS_NONE 0
|
||||
#define UPSSTATUS_OFF 1
|
||||
#define UPSSTATUS_OL 2
|
||||
#define UPSSTATUS_OB 4
|
||||
#define UPSSTATUS_LB 8
|
||||
#define UPSSTATUS_CAL 16
|
||||
#define UPSSTATUS_UNKOWN 32
|
||||
#define UPSSTATUS_NONE 0
|
||||
#define UPSSTATUS_OFF 1
|
||||
#define UPSSTATUS_OL 2
|
||||
#define UPSSTATUS_OB 4
|
||||
#define UPSSTATUS_LB 8
|
||||
#define UPSSTATUS_CAL 16
|
||||
#define UPSSTATUS_RB 32 /*Replace Battery */
|
||||
#define UPSSTATUS_UNKOWN 64
|
||||
|
||||
int server_port = PORT;
|
||||
char *server_address = "127.0.0.1";
|
||||
|
|
@ -96,7 +97,7 @@ double ups_utility_voltage = 0.0L;
|
|||
double ups_battery_percent = 0.0L;
|
||||
double ups_load_percent = 0.0L;
|
||||
double ups_temperature = 0.0L;
|
||||
char ups_status[MAX_INPUT_BUFFER] = "N/A";
|
||||
char *ups_status = "N/A";
|
||||
|
||||
int determine_status (void);
|
||||
int determine_supported_vars (void);
|
||||
|
|
@ -111,7 +112,7 @@ int
|
|||
main (int argc, char **argv)
|
||||
{
|
||||
int result = STATE_OK;
|
||||
char output_message[MAX_INPUT_BUFFER];
|
||||
char *message;
|
||||
char temp_buffer[MAX_INPUT_BUFFER];
|
||||
|
||||
double ups_utility_deviation = 0.0L;
|
||||
|
|
@ -134,35 +135,39 @@ main (int argc, char **argv)
|
|||
|
||||
if (determine_status () != OK)
|
||||
return STATE_CRITICAL;
|
||||
ups_status[0] = 0;
|
||||
asprintf (&ups_status, "");
|
||||
result = STATE_OK;
|
||||
|
||||
if (status & UPSSTATUS_OFF) {
|
||||
strcpy (ups_status, "Off");
|
||||
asprintf (&ups_status, "Off");
|
||||
result = STATE_CRITICAL;
|
||||
}
|
||||
else if ((status & (UPSSTATUS_OB | UPSSTATUS_LB)) ==
|
||||
(UPSSTATUS_OB | UPSSTATUS_LB)) {
|
||||
strcpy (ups_status, "On Battery, Low Battery");
|
||||
asprintf (&ups_status, "On Battery, Low Battery");
|
||||
result = STATE_CRITICAL;
|
||||
}
|
||||
else {
|
||||
if (status & UPSSTATUS_OL) {
|
||||
strcat (ups_status, "Online");
|
||||
asprintf (&ups_status, "%s%s", ups_status, "Online");
|
||||
}
|
||||
if (status & UPSSTATUS_OB) {
|
||||
strcat (ups_status, "On Battery");
|
||||
asprintf (&ups_status, "%s%s", ups_status, "On Battery");
|
||||
result = STATE_WARNING;
|
||||
}
|
||||
if (status & UPSSTATUS_LB) {
|
||||
strcat (ups_status, ", Low Battery");
|
||||
asprintf (&ups_status, "%s%s", ups_status, ", Low Battery");
|
||||
result = STATE_WARNING;
|
||||
}
|
||||
if (status & UPSSTATUS_CAL) {
|
||||
strcat (ups_status, ", Calibrating");
|
||||
asprintf (&ups_status, "%s%s", ups_status, ", Calibrating");
|
||||
}
|
||||
if (status & UPSSTATUS_RB) {
|
||||
asprintf (&ups_status, "%s%s", ups_status, ", Replace Battery");
|
||||
result = STATE_WARNING;
|
||||
}
|
||||
if (status & UPSSTATUS_UNKOWN) {
|
||||
strcat (ups_status, ", Unknown");
|
||||
asprintf (&ups_status, "%s%s", ups_status, ", Unknown");
|
||||
}
|
||||
}
|
||||
}
|
||||
|
|
@ -248,36 +253,27 @@ main (int argc, char **argv)
|
|||
alarm (0);
|
||||
|
||||
|
||||
sprintf (output_message, "UPS %s - ",
|
||||
(result == STATE_OK) ? "ok" : "problem");
|
||||
asprintf (&message, "UPS %s - ", (result == STATE_OK) ? "ok" : "problem");
|
||||
|
||||
if (supported_options & UPS_STATUS) {
|
||||
sprintf (temp_buffer, "Status=%s ", ups_status);
|
||||
strcat (output_message, temp_buffer);
|
||||
}
|
||||
if (supported_options & UPS_UTILITY) {
|
||||
sprintf (temp_buffer, "Utility=%3.1fV ", ups_utility_voltage);
|
||||
strcat (output_message, temp_buffer);
|
||||
}
|
||||
if (supported_options & UPS_BATTPCT) {
|
||||
sprintf (temp_buffer, "Batt=%3.1f%% ", ups_battery_percent);
|
||||
strcat (output_message, temp_buffer);
|
||||
}
|
||||
if (supported_options & UPS_LOADPCT) {
|
||||
sprintf (temp_buffer, "Load=%3.1f%% ", ups_load_percent);
|
||||
strcat (output_message, temp_buffer);
|
||||
}
|
||||
if (supported_options & UPS_TEMP) {
|
||||
sprintf (temp_buffer, "Temp=%3.1fF", ups_temperature);
|
||||
strcat (output_message, temp_buffer);
|
||||
}
|
||||
if (supported_options == UPS_NONE) {
|
||||
sprintf (temp_buffer,
|
||||
"UPS does not appear to support any available options\n");
|
||||
strcat (output_message, temp_buffer);
|
||||
}
|
||||
if (supported_options & UPS_STATUS)
|
||||
asprintf (&message, "%sStatus=%s ", message, ups_status);
|
||||
|
||||
printf ("%s\n", output_message);
|
||||
if (supported_options & UPS_UTILITY)
|
||||
asprintf (&message, "%sUtility=%3.1fV ", message, ups_utility_voltage);
|
||||
|
||||
if (supported_options & UPS_BATTPCT)
|
||||
asprintf (&message, "%sBatt=%3.1f%% ", message, ups_battery_percent);
|
||||
|
||||
if (supported_options & UPS_LOADPCT)
|
||||
asprintf (&message, "%sLoad=%3.1f%% ", message, ups_load_percent);
|
||||
|
||||
if (supported_options & UPS_TEMP)
|
||||
asprintf (&message, "%sTemp=%3.1fF", message, ups_temperature);
|
||||
|
||||
if (supported_options == UPS_NONE)
|
||||
asprintf (&message, "UPS does not support any available options\n");
|
||||
|
||||
printf ("%s\n", message);
|
||||
|
||||
return result;
|
||||
}
|
||||
|
|
@ -313,6 +309,8 @@ determine_status (void)
|
|||
status |= UPSSTATUS_LB;
|
||||
else if (!strcmp (ptr, "CAL"))
|
||||
status |= UPSSTATUS_CAL;
|
||||
else if (!strcmp (ptr, "RB"))
|
||||
status |= UPSSTATUS_RB;
|
||||
else
|
||||
status |= UPSSTATUS_UNKOWN;
|
||||
}
|
||||
|
|
|
|||
Loading…