icinga2/itl/plugins-contrib.d/ipmi.conf
Yonas Habteab 91c7e60df8 Replace all existing copyright headers with SPDX headers
I've used the following command to replace the original copyright header
lines in a C-style comment block:

```
$ find . \( -type d \( -name '\..*' -o -name third-party -o -name scripts -o -name prefix -o -name malloc -o -name server -o -name docker -o -name build -o -name doc \) -prune \) -o -type f -exec perl -pi -e 's{/\*[^*]*\(\s*c\s*\)\s*(\d{4})\s*Icinga\s+GmbH[^*]*\*/}{// SPDX-FileCopyrightText: \1 Icinga GmbH <https://icinga.com>\n// SPDX-License-Identifier: GPL-2.0-or-later}gi' {} +
```

For files that use shell-style comments (#) like CMakeLists.txt, I've
used this command:

```
$ find . \( -type d \( -name '\..*' -o -name third-party -o -name scripts -o -name prefix -o -name malloc -o -name server -o -name docker -o -name build -o -name doc \) -prune \) -o -type f -exec perl -pi -e 's{#.*\(\s*c\s*\)\s(\d{4})\sIcinga\s+GmbH.*}{# SPDX-FileCopyrightText: \1 Icinga GmbH <https://icinga.com>\n# SPDX-License-Identifier: GPL-2.0-or-later}gi' {} +
```

And for SQL files:

```
$ find . \( -type d \( -name '\..*' -o -name third-party -o -name scripts -o -name prefix -o -name malloc -o -name server -o -name docker -o -name build -o -name doc \) -prune \) -o -type f \( -name '*.sql' \) -exec perl -pi -e 's{--.*\(c\)\s(\d{4})\sIcinga\sGmbH.*}{-- SPDX-FileCopyrightText: \1 Icinga GmbH <https://icinga.com>\n-- SPDX-License-Identifier: GPL-2.0-or-later}gi' {} +
$ find . \( -type d \( -name '\..*' -o -name third-party -o -name scripts -o -name prefix -o -name malloc -o -name server -o -name docker -o -name build -o -name doc \) -prune \) -o -type f \( -name '*.sql' \) -exec perl -pi -e 's{-- Copyright \(c\)\s(\d{4})\sIcinga\s+Development\sTeam.*}{-- SPDX-FileCopyrightText: \1 Icinga GmbH <https://icinga.com>\n-- SPDX-License-Identifier: GPL-2.0-or-later}gi' {} +
```
2026-02-04 14:00:05 +01:00

124 lines
3.5 KiB
Text

// SPDX-FileCopyrightText: 2012 Icinga GmbH <https://icinga.com>
// SPDX-License-Identifier: GPL-2.0-or-later
object CheckCommand "ipmi-sensor" {
import "ipv4-or-ipv6"
command = [ PluginContribDir + "/check_ipmi_sensor" ]
arguments = {
"-H" = {
value = "$ipmi_address$"
description = "Hostname or ip address of the IPMI interface (default: host.address or host.address6)"
}
"-f" = {
value = "$ipmi_config_file$"
description = "Path to the FreeIPMI configuration file"
}
"-U" = {
value = "$ipmi_username$"
description = "Username to connect with"
}
"-P" = {
value = "$ipmi_password$"
description = "Password to use"
}
"-L" = {
value = "$ipmi_privilege_level$"
description = "Privilege level of the user"
}
"-b" = {
set_if = "$ipmi_backward_compatibility_mode$"
description = "Enable backward compatibility mode (for FreeIPMI 0.5.*)"
}
"-T" = {
value = "$ipmi_sensor_type$"
description = "Limit sensors to query based on IPMI sensor type (seperated by comma)"
}
"-ST" = {
value = "$ipmi_sel_type$"
description = "Limit SEL entries to specific types. (seperated by comma)"
}
"-x" = {
value = "$ipmi_exclude_sensor_id$"
description = "Exclude sensor matching ipmi_sensor_id"
}
"-xT" = {
value = "$ipmi_exclude_sensor$"
description = "Exclude sensors based on IPMI sensor type. (seperated by comma)"
}
"-xST" = {
value = "$ipmi_exclude_sel$"
description = "Exclude SEL entries of specific sensor types. (seperated by comma)"
}
"-i" = {
value = "$ipmi_sensor_id$"
description = "Include sensor matching ipmi_sensor_id"
}
"--nosel" = {
set_if = "$ipmi_no_sel_checking$"
description = "Turn off system event log checking via ipmi-sel"
}
"--nothresholds" = {
set_if = "$ipmi_no_thresholds$"
description = "Turn off performance data thresholds from output-sensor-thresholds"
}
"-D" = {
value = "$ipmi_protocol_lan_version$"
description = "Change the protocol LAN version (default: LAN_2_0)"
}
"-fc" = {
value = "$ipmi_number_of_active_fans$"
description = "Number of fans that should be active"
}
"--fru" = {
set_if = "$ipmi_show_fru$"
description = "Print the product serial number got by ipmi-fru"
}
"--assettag" = {
set_if = "$ipmi_show_assettag$"
description = "Print the assettag if it is available in the IPMI FRU data. (--fru is mandatory)"
}
"--board" = {
set_if = "$ipmi_show_board$"
description = "Print additional motherboard information if it is available in the IPMI FRU data. (--fru is mandatory)"
}
"--noentityabsent" = {
set_if = "$ipmi_noentityabsent$"
description = "Skip sensor checks for sensors that have 'noentityabsent' as event state"
}
"-vv" = {
set_if = "$ipmi_verbose$"
description = "Be Verbose multi line output, also with additional details for warnings"
}
"-vvv" = {
set_if = "$ipmi_debug$"
description = "Be Verbose debugging output, followed by normal multi line output"
}
"-us" = {
value = "$ipmi_unify_file$"
description = "Path to the unify file to unify sensor names."
}
}
vars.ipmi_address = "$check_address$"
vars.ipmi_protocol_lan_version = "LAN_2_0"
}
/*
* Icinga2 CheckCommand definition for an IPMI interface ping check
*/
template CheckCommand "ipmi-alive-common" {
vars.ping_wrta = 5000.0
vars.ping_wpl = 100
vars.ping_crta = 5000.0
vars.ping_cpl = 100
vars.ping_packets = 1
}
object CheckCommand "ipmi-alive" {
import "ping"
import "ipmi-alive-common"
}