erplibre/script/odoo/migration/smoke_public_url.py
Mathieu Benoit e214df7329 [FIX] smoke: judge the back office AFTER the repair, and say why it failed
No timeout was hit and no test was skipped. The back office failed for the
same reason the site did: the COW copy of website.submenu breaks
/web/login exactly as it breaks the public pages — both go through the
same layout. The pass simply ran BEFORE the reset, and unlike the URLs it
was never looked at again. It is now, on the same second server.

« Session expired » described the consequence and hid the cause. The login
page returned 500 and nothing said so, so one looks at the password. The
status of that page, and a missing CSRF token, are now named.

Diagnosing this, I started Odoo 18 on a 17 database and got 500 on all
thirty-seven URLs and on /web/login: a report that says the site is
entirely broken when nothing is. database_cleanup already refused that;
the smoke tools now share the same guard rather than reimplementing it.

--- FR ---

[FIX] smoke : juger le back-office APRÈS la réparation, et dire pourquoi

Aucun délai n'a été atteint et aucun test n'a été sauté. Le back-office a
échoué pour la raison même qui cassait le site : la copie COW de
website.submenu casse /web/login comme elle casse les pages publiques —
les deux passent par le même gabarit. La passe tournait avant la
réinitialisation et, contrairement aux URL, n'était jamais revue.

« Session expired » décrivait la conséquence et cachait la cause : la page
de connexion rendait 500 sans que rien ne le dise, et l'on cherchait du
côté du mot de passe.

En diagnostiquant, j'ai lancé un Odoo 18 sur une base 17 : 500 partout, un
rapport qui déclare le site entièrement cassé quand rien ne l'est.
database_cleanup refusait déjà cela ; les outils de fumée partagent
désormais sa garde au lieu d'en écrire une seconde.

Assisted-by: Claude Opus 5
2026-08-22 07:23:59 -04:00

914 lines
32 KiB
Python
Executable file
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

#!/usr/bin/env python3
# © 2021-2026 TechnoLibre (http://www.technolibre.ca)
# License AGPL-3.0 or later (http://www.gnu.org/licenses/agpl)
"""Request every public URL of a migrated database, and report what breaks.
Why this exists
---------------
A migration can finish, load every module, and still serve a 500 on a page
nobody thought to open. Measured on a real one: ``/blog/<blog>/post/<post>``
answered 500 because a COW copy frozen on the previous version no longer held
the section a child view xpaths into. Nothing in the migration log said so —
the module loading had succeeded.
Where the list comes from
-------------------------
``/sitemap.xml``: the list Odoo itself publishes for search engines, built by
``website.enumerate_pages()``. It covers the controller routes declared with
``sitemap=True`` and the records behind them — pages, blog posts, products.
It cannot be read from ``odoo-bin shell``: ``enumerate_pages()`` asks for
``http.root.get_db_router(request.db)`` and raises « object unbound » without
a real request. So the server is started, asked, and stopped.
What counts as a failure
------------------------
Any status >= 400. The sitemap is the PUBLIC list: a page listed there and
answering 403 or 404 is as wrong as one answering 500, just less loud.
Exit codes: 0 every URL answered, 1 some failed, 2 the tool failed.
"""
import argparse
import os
import re
import signal
import socket
import subprocess
import sys
import time
import urllib.error
import urllib.parse
import urllib.request
sys.path.append(
os.path.normpath(os.path.join(os.path.dirname(__file__), "..", "..", ".."))
)
try:
from script.todo.todo_i18n import t
except Exception: # pragma: no cover - repli si i18n indisponible
def t(key: str) -> str:
return key
try:
from script.todo import auto_ask
except Exception: # pragma: no cover - repli si le pilote est absent
auto_ask = None
def can_ask():
"""Peut-on poser une question ICI ?
Il faut deux choses, pas une : de quoi LIRE la réponse (stdin sur un
terminal) et de quoi MONTRER la question (stdout aussi). Ne tester que
stdin laisse poser une invite qui part dans un tube : elle reste en
tampon, invisible, pendant que le processus attend — on croit à un
blocage et l'on tape Entrée à l'aveugle.
"""
return sys.stdin.isatty() and sys.stdout.isatty()
RE_LOC = re.compile(r"<loc>\s*([^<\s]+)\s*</loc>", re.I)
# « [view_id: 3282, xml_id: n/a, model: n/a, parent_id: 3281] ». Seule la
# phrase qui précède est traduite ; cette ligne-ci ne l'est pas, donc la lire
# marche dans les deux langues. Le PARENT est le coupable : c'est la copie
# figée dans laquelle l'enfant ne trouve plus son xpath.
RE_CONTEXT = re.compile(r"\[view_id: (\d+),.*?parent_id: (\d+)\]")
# « Template: website.submenu ». Une QWebException de RENDU ne porte pas le
# bloc [view_id …] : elle nomme le gabarit. Mesuré au palier 17 — une copie
# figée appelait `submenu.clean_url()`, méthode renommée `_clean_url()` dans
# la version, et 34 URL sur 37 rendaient 500 sans que rien ne désigne la vue
# fautive.
RE_TEMPLATE = re.compile(r"^Template:\s*([\w.]+)\s*$", re.M)
# Un port à part : la migration tourne souvent à côté d'une instance vivante,
# et lui voler 8069 ferait échouer le test pour une raison sans rapport.
DEFAULT_PORT = 8169
def run_psql(database, sql):
"""Lecture seule, garantie par le serveur PostgreSQL lui-même."""
env = os.environ.copy()
env["PGOPTIONS"] = "-c default_transaction_read_only=on"
env["PSQLRC"] = ""
done = subprocess.run(
["psql", "-X", "-w", "-d", database, "-tAF", "\x1f", "-c", sql],
capture_output=True,
text=True,
env=env,
)
if done.returncode:
return []
return [line.split("\x1f") for line in done.stdout.splitlines() if line]
def require_matching_version(database):
"""Refuser de démarrer sur une base d'une autre version qu'un Odoo.
Sans cela le rapport ment de la pire façon : mesuré ici même, un
checkout passé en 18.0 démarré sur une base 17.0 rend 500 sur les
trente-sept URL et sur /web/login, et l'on conclut à un site
entièrement cassé alors que rien ne l'est. Le checkout suit la
migration ; rien ne garantit qu'il soit resté sur la version de la
base qu'on veut interroger.
On délègue à `database_cleanup`, qui porte déjà cette garde : deux
implémentations divergeraient, et une garde qui diverge ne garde rien.
"""
sys.path.insert(0, os.path.dirname(os.path.abspath(__file__)))
try:
from database_cleanup import require_matching_version as verifier
except ImportError:
return None
return verifier(database)
def start_server(database, port, config_path="./config.conf", log_path=None):
"""Démarrer Odoo, son journal dans un FICHIER.
Pas un tube : Python bufferise par blocs quand sa sortie n'est pas un
terminal, et un fil de lecture court alors après des lignes qui n'ont
pas encore été écrites. Mesuré — 24 lignes vues sur 198, et la trace qui
nomme la vue fautive faisait partie des absentes. Un fichier se relit
entièrement, quand on veut.
"""
handle = open(log_path, "w", encoding="utf-8") if log_path else None
server = subprocess.Popen(
[
"./run.sh",
"-c",
config_path,
"-d",
database,
"--http-port",
str(port),
"--log-level=warn",
# Deux lignes par requête, et elles portent le CHEMIN. Sans
# elles une trace du journal ne peut être rattachée à rien :
# on l'attribuait à la dernière requête, qui n'était pas la
# sienne. Mesuré — /my accusé d'une panne appartenant à une
# application testée après lui.
"--log-handler=werkzeug:INFO",
],
stdout=handle or subprocess.DEVNULL,
stderr=subprocess.STDOUT,
text=True,
# Son propre groupe de processus : « ./run.sh » est un script bash
# qui ne transmet rien à son enfant. Un terminate() sur lui tuait le
# script et laissait odoo-bin vivant, tenant le port. L'essai suivant
# démarrait alors un serveur qui ne pouvait pas se lier, et
# interrogeait sans le savoir CELUI D'AVANT — mesuré, deux fois.
start_new_session=True,
)
server.erplibre_log = handle
return server
def read_log(log_path):
"""Le journal du serveur, tel qu'écrit jusqu'ici."""
if not log_path or not os.path.isfile(log_path):
return []
with open(log_path, "r", encoding="utf-8", errors="replace") as handle:
return handle.read().splitlines()
def fetch(url, timeout=30):
"""(statut, corps). Statut 0 quand la connexion elle-même échoue."""
try:
with urllib.request.urlopen(url, timeout=timeout) as answer:
return answer.getcode(), answer.read().decode(
"utf-8", errors="replace"
)
except urllib.error.HTTPError as exc:
return exc.code, exc.read().decode("utf-8", errors="replace")
except Exception:
return 0, ""
def wait_ready(base_url, timeout=180, sleep=2):
"""Attendre que le serveur réponde. False s'il n'est jamais venu."""
deadline = time.time() + timeout
while time.time() < deadline:
status, _body = fetch(base_url + "/web/login", timeout=5)
if status:
return True
time.sleep(sleep)
return False
def sitemap_urls(base_url):
"""Les URL du sitemap, index compris, ramenées sur l'hôte local.
Le sitemap porte le domaine du site (technolibre.ca) ; on teste une base
servie en local. Garder le domaine ferait interroger la production —
c'est le genre d'erreur qui ne se voit qu'après.
"""
status, body = fetch(base_url + "/sitemap.xml")
if not status or status >= 400:
return [], status
lst_loc = RE_LOC.findall(body)
# Un index de sitemaps ne contient que des sitemaps : on descend d'un cran.
if "<sitemapindex" in body.lower():
lst_page = []
for loc in lst_loc:
_status, sub = fetch(local_url(base_url, loc))
lst_page.extend(RE_LOC.findall(sub))
lst_loc = lst_page
seen, lst_url = set(), []
for loc in lst_loc:
url = local_url(base_url, loc)
if url not in seen:
seen.add(url)
lst_url.append(url)
return lst_url, status
def local_url(base_url, loc):
"""Remplacer le schéma et l'hôte du sitemap par ceux qu'on teste."""
parsed = urllib.parse.urlparse(loc)
path = parsed.path or "/"
if parsed.query:
path += "?" + parsed.query
return base_url.rstrip("/") + path
# Odoo écrit sa trace APRÈS avoir répondu, et par le tube d'un script shell :
# mesuré, elle peut arriver près de trois secondes plus tard. Une demi-seconde
# concluait « aucune vue en cause » sur des pages qui en nommaient une.
LOG_DELAY = 3.0
def attach_missing_parents(lst_failure, lst_log):
"""Repêcher les contextes arrivés trop tard pour leur tranche.
Le découpage par URL est une commodité, pas une garantie : le journal est
asynchrone. Ce second passage lit TOUT ce qui a été capturé et rattache
ce qui n'avait été rattaché à rien — mieux vaut un coupable mal attribué
qu'un coupable perdu.
"""
known = {pid for _u, _s, lst in lst_failure for pid in lst}
extra = []
for line in lst_log:
# LES DEUX : le parent ET l'enfant. Mesuré sur /contactus — le
# parent était identique à sa vue module, et c'est l'ENFANT qui
# portait l'arch périmée. Ne proposer que le parent envoyait
# réinitialiser une copie qui allait déjà bien.
for view_id, parent_id in RE_CONTEXT.findall(line):
for candidate in (parent_id, view_id):
if candidate not in known and candidate not in extra:
extra.append(candidate)
if not extra:
return lst_failure
rebuilt = []
placed = False
for url, status, lst_parent in lst_failure:
if not lst_parent and not placed:
lst_parent = list(extra)
placed = True
rebuilt.append((url, status, lst_parent))
if not placed and rebuilt:
url, status, lst_parent = rebuilt[0]
rebuilt[0] = (url, status, lst_parent + extra)
return rebuilt
def check_urls(lst_url, timeout=30):
"""[(url, statut, [])] pour celles qui ont échoué.
Les vues en cause sont rattachées après coup, en relisant le journal du
serveur : elles y arrivent quand Odoo vide son tampon, pas quand la
requête revient.
"""
lst_failure = []
for url in lst_url:
status, _body = fetch(url, timeout=timeout)
if status == 0 or status >= 400:
lst_failure.append((url, status, []))
return lst_failure
def template_keys(lst_log, database):
"""Les gabarits nommés par une QWebException, s'ils ont une copie COW.
Nommer une clé sans copie enverrait réinitialiser une vue module — donc
ne rien faire, en silence. On ne propose que ce qui peut l'être.
"""
lst_key = []
for line in lst_log:
for key in RE_TEMPLATE.findall(line):
if key not in lst_key:
lst_key.append(key)
if not lst_key:
return []
quoted = ",".join("'" + k.replace("'", "''") + "'" for k in lst_key)
rows = run_psql(
database,
"SELECT DISTINCT key FROM ir_ui_view"
f" WHERE website_id IS NOT NULL AND key IN ({quoted});",
)
with_copy = {row[0] for row in rows if row and row[0]}
return [key for key in lst_key if key in with_copy]
def culprit_keys(database, lst_failure):
"""Les clés des vues parentes mises en cause, sans doublon.
C'est ce qu'on passe à reset_stale_cow_views : il travaille par clé, et
relever un identifiant dans une trace pour le traduire à la main est
exactement la recopie où l'on se trompe.
"""
lst_id = []
for _url, _status, lst_parent in lst_failure:
for parent_id in lst_parent:
if parent_id not in lst_id:
lst_id.append(parent_id)
if not lst_id:
return []
ids = ",".join(str(int(x)) for x in lst_id)
rows = run_psql(
database,
f"SELECT id, key, website_id FROM ir_ui_view WHERE id IN ({ids})"
" AND key IS NOT NULL ORDER BY id;",
)
lst_key = []
for row in rows:
if len(row) >= 2 and row[1] and row[1] not in lst_key:
lst_key.append(row[1])
return lst_key
def render(lst_url, lst_failure, lst_key=None):
if not lst_url:
return f"⚠️ {t('The sitemap listed no URL: nothing was tested.')}\n"
if not lst_failure:
return (
f"✅ -> {len(lst_url)} {t('public URL(s) answered without error.')}"
"\n"
)
lines = [
f"❌ {len(lst_failure)} {t('of')} {len(lst_url)}"
f" {t('public URL(s) failed')} :"
]
for url, status, lst_parent in lst_failure:
label = status or t("no answer")
lines.append(f" [{label}] {url}")
if lst_parent:
lines.append(
f" {t('parent view(s) in cause')} :"
f" {', '.join(lst_parent)}"
)
if lst_key:
lines.append(
f" {t('Those parents are copies frozen on an older version;')}"
f" {t('resetting them onto the module view is the fix')} :"
)
for key in lst_key:
lines.append(f" {key}")
lines.append(
f" {t('A page listed for search engines that does not answer is')}"
f" {t('a page your visitors do not reach either.')}"
)
return "\n".join(lines) + "\n"
def apply_reset(database, lst_key):
"""Réinitialiser ces copies sur leur vue module. ÉCRIT en base.
On délègue à reset_stale_cow_views : il sauvegarde l'arch précédente
avant d'écrire, et c'est déjà lui qu'on documente partout ailleurs. En
refaire une seconde version ici, c'est se donner deux comportements à
tenir d'accord.
"""
cmd = [
sys.executable,
os.path.join(
"script", "odoo", "migration", "reset_stale_cow_views.py"
),
"-d",
database,
]
for key in lst_key:
cmd += ["--reset", key]
cmd.append("--apply")
done = subprocess.run(cmd, capture_output=True, text=True)
return done.returncode, done.stdout + done.stderr
DEFAULT_ANSWER = "a"
def prompt(database, lst_failure, lst_key, ask=None):
"""Proposer de corriger, puis dire ce qu'il reste. Rend les clés traitées.
Détecter sans offrir le geste, c'est laisser relever des identifiants
dans une trace pour les traduire en clés à la main — au moment précis où
l'on veut juste que la page réponde.
"""
if not lst_key:
print(f"ℹ -> {t('No parent view named: nothing to offer.')}")
return []
if ask is None:
# Lancé à part par la migration : sans lecteur temporisé, cette
# question arrêtait net une exécution automatique.
ask = (
auto_ask.make_ask(DEFAULT_ANSWER)
if auto_ask
else (lambda prompt="": input(prompt) or DEFAULT_ANSWER)
)
print(f"\n✨ {t('Copies to reset onto their module view')} :")
for index, key in enumerate(lst_key, start=1):
print(f" [{index}] {key}")
print(f" [a] {t('All of the list above')}")
answer = (
ask(
f"💬 {t('Which one(s) to reset?')}"
f" ({t('numbers separated by commas, Enter = all, n =')}"
f" {t('nothing')}) : "
)
.strip()
.lower()
)
# « n », et non plus le vide : Entrée vaut « toutes » maintenant, et une
# sortie sans mot pour dire non serait une sortie sans issue.
if not answer or answer == "n":
print(f"ℹ -> {t('Kept. Nothing was reset.')}")
return []
if answer == "a":
lst_chosen = list(lst_key)
else:
lst_chosen = []
for part in answer.replace(" ", "").split(","):
if part.isdigit() and 1 <= int(part) <= len(lst_key):
lst_chosen.append(lst_key[int(part) - 1])
if not lst_chosen:
print(f"⚠️ {t('Unknown choice, nothing was reset.')}")
return []
status, output = apply_reset(database, lst_chosen)
print(output.strip()[-2000:])
if status == 2:
print(f"❌ {t('Reset failed, nothing was changed.')}")
return []
return lst_chosen
def render_internal(internal):
"""Afficher le rapport du back-office. Rend True s'il a échoué.
Ne rien afficher quand la base n'a pas été neutralisée serait laisser
croire que le back-office a été testé et qu'il va bien.
"""
if internal is None:
return False
reprise = f" ({t('after the reset')})" if internal.get("retried") else ""
if "skipped" in internal:
if internal.get("loud"):
# Un saut ATTENDU se dit à voix basse ; un saut qui trahit une
# panne doit compter comme un échec, sinon le code de sortie
# annonce que tout va bien.
print(
f"\n⚠️ {t('Back office NOT browsed')}{reprise} :"
f" {internal['skipped']}"
)
return True
print(
f"\nℹ️ {t('Back office not browsed')}{reprise} :"
f" {internal['skipped']}"
)
return False
import smoke_internal_ui
print(smoke_internal_ui.render(internal["results"], internal["failures"]))
return bool(internal["failures"])
def attach_internal_log(internal_report, log_path):
"""Donner à la passe back-office la trace que sa page ne montrait pas.
APRÈS l'arrêt du serveur, et pas avant : un serveur qui écrit dans un
fichier bufferise et ne vide qu'en s'arrêtant. La page d'erreur d'Odoo
en production, elle, se contente de « 500: Internal Server Error » —
de quoi constater, pas de quoi réparer.
"""
if not internal_report or not internal_report.get("failures"):
return
try:
import smoke_internal_ui
except ImportError:
return
smoke_internal_ui.attach_log_reason(
internal_report["failures"], read_log(log_path)
)
def internal_needs_retry(internal_report):
"""Le back-office mérite-t-il un second essai après la réparation ?
Oui s'il a échoué, et oui aussi s'il a été SAUTÉ : « connexion
impossible » est justement le symptôme d'un site cassé, et c'est ce
que la réinitialisation vient de réparer.
"""
if not internal_report:
return False
return bool(
internal_report.get("failures") or internal_report.get("skipped")
)
def internal_phase(
base_url,
database,
enabled=True,
login="test",
password="test",
limit=20,
every_menu=False,
lst_portal=None,
required=False,
):
"""Le back-office, si la base a été neutralisée. Rend None sinon.
La condition n'est pas un drapeau mais l'utilisateur lui-même : la
neutralisation pose un compte `test` avec les groupes du
superutilisateur, et c'est le seul moyen d'entrer sans connaître le mot
de passe de quelqu'un. Une migration reprise a pu sauter l'étape, et le
fichier de progression dirait quand même « fait ».
Un échec ICI ne doit pas emporter le test public : il est mesuré, il
est rapporté, mais le rapport des URL publiques a sa propre valeur.
"""
if not enabled:
return None
try:
import smoke_internal_ui
except ImportError:
# Se taire ici ferait disparaître la passe ENTIÈRE sans un mot, et
# l'on croirait le back-office testé. Un outil absent est une
# panne d'installation, pas une base saine.
return {"skipped": t("smoke_internal_ui.py is missing"), "loud": True}
etat = smoke_internal_ui.user_state(database, login, run_psql=run_psql)
if etat == "absent":
# `required` dit que la migration a NEUTRALISÉ cette base : le
# compte devrait donc y être. Mesuré — il survit jusqu'au palier
# 15 puis disparaît, et la passe s'arrêtait sans bruit exactement
# là où une migration fait le plus de dégâts.
if required:
return {
"skipped": t(
"the test user is gone from a neutralized"
" database: the back office was NOT checked"
),
"loud": True,
}
return {"skipped": t("no test user: the database was not neutralized")}
if etat != "present":
# « je ne sais pas » n'est pas « tout va bien » : le dire autrement
# ferait passer un back-office jamais ouvert pour un back-office sain.
return {
"skipped": t("could not tell whether the test user exists"),
"loud": True,
}
try:
lst_result, lst_failure = smoke_internal_ui.run(
base_url,
database,
login,
password,
limit,
every_menu=every_menu,
lst_portal=(
smoke_internal_ui.DEFAULT_PORTAL_PATHS
if lst_portal is None
else lst_portal
),
)
except RuntimeError as exc:
return {"skipped": str(exc)}
return {"results": lst_result, "failures": lst_failure}
def run(
database,
port,
config_path,
limit=None,
timeout=30,
boot=180,
interactive=False,
auto_apply=False,
ask=None,
internal=True,
internal_login="test",
internal_password="test",
internal_limit=20,
every_menu=False,
portal=None,
internal_required=False,
):
"""Démarrer, interroger, arrêter, LIRE, éventuellement corriger, revérifier.
L'ordre porte tout le correctif : un serveur qui écrit dans un fichier
bufferise et ne vide qu'en s'arrêtant. Lire avant l'arrêt donnait
vingt-quatre lignes de démarrage et zéro trace — donc « aucune vue en
cause » sur des pages qui en nommaient une. Mesuré deux fois avant d'être
compris.
"""
import tempfile
base_url = f"http://127.0.0.1:{port}"
log_path = os.path.join(
tempfile.gettempdir(), f"erplibre_smoke_{database}_{port}.log"
)
mismatch = require_matching_version(database)
if mismatch:
raise RuntimeError(mismatch)
if port_is_taken(port):
raise RuntimeError(
f"{t('Something already listens on port')} {port} :"
f" {t('it would be tested instead of this database.')}"
)
server = start_server(database, port, config_path, log_path=log_path)
try:
if not wait_ready(base_url, timeout=boot):
raise RuntimeError(
f"{t('The server never answered on')} {base_url}"
)
lst_url, status = sitemap_urls(base_url)
if not status:
raise RuntimeError(f"{t('Could not read')} {base_url}/sitemap.xml")
if limit:
lst_url = lst_url[:limit]
lst_failure = check_urls(lst_url, timeout=timeout)
# ICI, pendant que le serveur tourne : le démarrage d'Odoo est ce
# qui coûte des minutes, pas les requêtes. Un deuxième outil avec
# son propre serveur doublerait l'attente pour rien.
internal_report = internal_phase(
base_url,
database,
enabled=internal,
login=internal_login,
password=internal_password,
limit=internal_limit,
every_menu=every_menu,
lst_portal=portal,
required=internal_required,
)
finally:
stop_server(server)
attach_internal_log(internal_report, log_path)
lst_key = []
if lst_failure:
lst_log = read_log(log_path)
lst_failure = attach_missing_parents(lst_failure, lst_log)
lst_key = culprit_keys(database, lst_failure)
# Les deux sources : le contexte d'héritage quand il existe, le nom
# du gabarit quand l'échec vient du rendu.
for key in template_keys(lst_log, database):
if key not in lst_key:
lst_key.append(key)
if not lst_failure or not (interactive or auto_apply):
return lst_url, lst_failure, lst_key, None, internal_report
print(render(lst_url, lst_failure, lst_key))
if auto_apply:
lst_done = lst_key
if lst_done:
code, output = apply_reset(database, lst_done)
print(output.strip()[-2000:])
if code == 2:
lst_done = []
else:
# `ask=None` et non `input` : c'est `prompt` qui sait quel défaut
# lui appartient, et qui pose alors la question par le lecteur
# temporisé. Forcer `input` ici court-circuitait le mode auto —
# mesuré, l'invite attendait indéfiniment une frappe pendant une
# migration lancée en auto-exécution.
lst_done = prompt(database, lst_failure, lst_key, ask=ask)
if not lst_done:
return lst_url, lst_failure, lst_key, None, internal_report
lst_again, internal_report = recheck_after_reset(
database,
port,
config_path,
base_url,
log_path,
lst_failure,
internal_report,
timeout=timeout,
boot=boot,
internal=internal,
internal_login=internal_login,
internal_password=internal_password,
internal_limit=internal_limit,
every_menu=every_menu,
portal=portal,
internal_required=internal_required,
)
return lst_url, lst_failure, lst_key, lst_again, internal_report
def recheck_after_reset(
database,
port,
config_path,
base_url,
log_path,
lst_failure,
internal_report,
timeout=30,
boot=180,
internal=True,
internal_login="test",
internal_password="test",
internal_limit=20,
every_menu=False,
portal=None,
internal_required=False,
):
"""Redémarrer, et revoir ce qui avait échoué. Rend (URL, back-office).
Le back-office est REJUGÉ lui aussi, et ce n'est pas une symétrie
gratuite : la copie COW qui casse le site casse AUSSI /web/login — les
deux passent par le même gabarit. La passe interne tournait donc avant
la réparation et rapportait « connexion impossible » sur une base que
la réinitialisation remettait d'aplomb quelques secondes plus tard.
"""
server = start_server(database, port, config_path, log_path=log_path)
try:
if not wait_ready(base_url, timeout=boot):
raise RuntimeError(
f"{t('The server never answered on')} {base_url}"
)
lst_again = check_urls(
[url for url, _s, _p in lst_failure], timeout=timeout
)
if internal_needs_retry(internal_report):
reprise = internal_phase(
base_url,
database,
enabled=internal,
login=internal_login,
password=internal_password,
limit=internal_limit,
every_menu=every_menu,
lst_portal=portal,
required=internal_required,
)
if reprise is not None:
internal_report = reprise
internal_report["retried"] = True
finally:
stop_server(server)
return lst_again, internal_report
def stop_server(server):
"""Arrêter tout le GROUPE : sinon odoo-bin survit à son script."""
try:
group = os.getpgid(server.pid)
except OSError:
group = None
if group is not None:
try:
os.killpg(group, signal.SIGTERM)
except OSError:
pass
try:
server.wait(timeout=30)
except subprocess.TimeoutExpired:
if group is not None:
try:
os.killpg(group, signal.SIGKILL)
except OSError:
pass
server.kill()
handle = getattr(server, "erplibre_log", None)
if handle:
handle.close()
def port_is_taken(port, host="127.0.0.1"):
"""Quelqu'un écoute-t-il déjà là ?
Sans cette question, un serveur resté d'un essai précédent répond à
« le serveur est-il prêt ? », et l'on teste sa base à lui en croyant
tester la sienne. C'est exactement ce qui est arrivé ici.
"""
with socket.socket(socket.AF_INET, socket.SOCK_STREAM) as sock:
sock.settimeout(1)
return sock.connect_ex((host, port)) == 0
def main(argv=None):
parser = argparse.ArgumentParser(
description=(
"Start Odoo on a database, request every URL of its sitemap, and"
" report those that fail."
)
)
parser.add_argument("-d", "--database", required=True)
parser.add_argument("-c", "--config", default="./config.conf")
parser.add_argument("-p", "--port", type=int, default=DEFAULT_PORT)
parser.add_argument(
"--limit", type=int, default=None, help="test only the first N URLs"
)
parser.add_argument("--timeout", type=int, default=30)
parser.add_argument(
"--apply",
action="store_true",
help="reset the views in cause without asking (WRITES)",
)
parser.add_argument(
"--report-only",
action="store_true",
help="never ask anything, even in front of a terminal",
)
parser.add_argument(
"--boot-timeout",
type=int,
default=180,
help="how long to wait for the server to answer",
)
parser.add_argument(
"--no-internal",
action="store_true",
help="skip the back-office pass done as the neutralization test user",
)
parser.add_argument("--login", default="test")
parser.add_argument("--password", default="test")
parser.add_argument(
"--record-limit",
type=int,
default=20,
help="how many records each app loads on its first page",
)
parser.add_argument(
"--all-menus",
action="store_true",
help="open every menu with an action, not just each app's first page",
)
parser.add_argument(
"--internal-required",
action="store_true",
help="the database WAS neutralized: a missing test user is a failure",
)
parser.add_argument(
"--portal",
default="/my",
help="portal paths opened while signed in (comma separated, empty"
" to skip)",
)
config = parser.parse_args(argv)
print(
f"⧖ {t('Starting Odoo on')} '{config.database}'"
f" ({t('port')} {config.port})…"
)
interactive = not config.report_only and can_ask()
try:
lst_url, lst_failure, lst_key, lst_again, internal = run(
config.database,
config.port,
config.config,
limit=config.limit,
timeout=config.timeout,
boot=config.boot_timeout,
interactive=interactive,
auto_apply=config.apply,
internal=not config.no_internal,
internal_login=config.login,
internal_password=config.password,
internal_limit=config.record_limit,
every_menu=config.all_menus,
internal_required=config.internal_required,
portal=[
path.strip()
for path in (config.portal or "").split(",")
if path.strip()
],
)
except RuntimeError as exc:
print(f"❌ {exc}")
return 2
internal_failed = render_internal(internal)
if lst_again is None:
print(render(lst_url, lst_failure, lst_key))
return 1 if (lst_failure or internal_failed) else 0
# Après correction on ne redit pas le diagnostic : on dit ce qu'il RESTE.
print(
f"\n↻ {t('Re-checked the')} {len(lst_failure)}"
f" {t('failing URL(s) after the reset')} :"
)
print(render([url for url, _s, _p in lst_failure], lst_again, None))
return 1 if (lst_again or internal_failed) else 0
if __name__ == "__main__":